Peptide adsorption to vial and tube walls
Peptides in dilute solution can stick to the walls of glass and plastic containers fast enough that most of the material is gone before it is measured, so container choice is part of the method, not an afterthought.
Nonspecific binding, or adsorption, is the loss of peptide from solution onto the surfaces it touches: vials, tubes, pipette tips, and autosampler inserts. It is driven by charge and hydrophobicity, so cationic and amphipathic sequences tend to bind glass, while hydrophobic stretches favor polypropylene and polystyrene. The loss is largest at low concentrations, where a surface can take up a large fraction of the total material, and it produces assay results that look like low potency, poor recovery, or batch-to-batch drift when the material itself is fine.
The size of the effect is not small. Kristensen and colleagues, PLoS One, 2015 (PMID 25932639) used analytical HPLC to quantify adsorption of three cationic membrane-active peptides, mastoparan X, melittin, and magainin 2, to common glass and plastic sample containers and found that at typical experimental concentrations 90% or more of the peptide could be lost from solution through rapid binding to the container walls. Goebel-Stengel and colleagues, Analytical Biochemistry, 2011 (PMID 21315060) incubated eight radiolabeled endocrine peptides of varied charge, size, and modification for 48 hours in untreated and siliconized glass and plastic tubes. Recovery differed widely by surface and peptide, siliconization decreased recovery, adding 1% bovine serum albumin improved it, and lyophilizing with BSA in the best tube for each peptide gave more than 89% recovery for all of them.
Analytical work runs into the same problem. Bongaerts and colleagues, Journal of Pharmaceutical and Biomedical Analysis, 2023 (PMID 36868028) traced nonspecific binding through each sample-preparation step of an LC-MS/MS method for two neuropeptides and found that adding 0.05% plasma as an adsorption competitor was essential to avoid losses, with larger peptides harder to handle than short ones. The practical reading for a lab: no single container is best for every sequence, so test recovery for the peptide in hand, prepare dilute working solutions close to use, consider a carrier protein or competitor where the assay allows it, and keep stock material lyophilized until needed. A low result on a dilute sample is worth checking against the certificate of analysis before blaming the material. This note summarizes published peptide chemistry. It is not dosing or human-use guidance.